ipmi-config(8)


NAME

   ipmi-config - configure IPMI values

SYNOPSIS

   ipmi-config [OPTION...]

DESCRIPTION

   ipmi-config is used to get and set configuration parameters in IPMI. In
   can be used to configured usernames, passwords, networking information,
   security,  Serial-over-LAN  (SOL), Platform Event Filtering (PEF), boot
   devices, power restoration policy, sensor  thresholds,  sensor  events,
   and  many  more configuration options.  Some configuration is typically
   required before most IPMI  tools  can  be  used  to  access  a  machine
   remotely.  By default, ipmi-config, will let you --checkout or --commit
   only the  core  IPMI  values  necessary  for  IPMI  configuration.  For
   additional   advanced   configuration   fields   related   to   Chassis
   configuration (including boot options), Platform Event Filtering (PEF),
   or   Sensors,  see  the  --category  option  below.   The  majority  of
   configuration operations require ADMIN privilege when using ipmi-config
   out-of-band.  Although  connecting  via a user with ADMIN privileges is
   not required for out-of-band use, the vast  majority  of  configuration
   options will not be retrieved or set.

   Listed  below  are general IPMI options, tool specific options, trouble
   shooting  information,  workaround  information,  examples,  and  known
   issues.  For a general introduction to FreeIPMI please see freeipmi(7).
   See GENERAL USE below for a description on basic use of ipmi-config.

GENERAL OPTIONS

   The  following  options  are  general  options  for  configuring   IPMI
   communication and executing general tool commands.

   -D IPMIDRIVER, --driver-type=IPMIDRIVER
          Specify  the  driver  type  to  use  instead  of  doing  an auto
          selection.  The currently available outofband  drivers  are  LAN
          and  LAN_2_0,  which perform IPMI 1.5 and IPMI 2.0 respectively.
          The currently available inband drivers are KCS, SSIF,  OPENIPMI,
          SUNBMC, and INTELDCMI.

   --disable-auto-probe
          Do not probe in-band IPMI devices for default settings.

   --driver-address=DRIVER-ADDRESS
          Specify  the  in-band  driver  address to be used instead of the
          probed value. DRIVER-ADDRESS should be prefixed with "0x" for  a
          hex value and '0' for an octal value.

   --driver-device=DEVICE
          Specify the in-band driver device path to be used instead of the
          probed path.

   --register-spacing=REGISTER-SPACING
          Specify the in-band  driver  register  spacing  instead  of  the
          probed  value. Argument is in bytes (i.e. 32bit register spacing
          = 4)

   --target-channel-number=CHANNEL-NUMBER
          Specify the in-band driver target channel number  to  send  IPMI
          requests to.

   --target-slave-address=SLAVE-ADDRESS
          Specify  the  in-band  driver  target  slave number to send IPMI
          requests to.

   -h                                             IPMIHOST1,IPMIHOST2,...,
   --hostname=IPMIHOST1[:PORT],IPMIHOST2[:PORT],...
          Specify   the  remote  host(s)  to  communicate  with.  Multiple
          hostnames may be separated by comma or may  be  specified  in  a
          range format; see HOSTRANGED SUPPORT below. An optional port can
          be specified with  each  host,  which  may  be  useful  in  port
          forwarding or similar situations.

   -u USERNAME, --username=USERNAME
          Specify  the username to use when authenticating with the remote
          host.  If not specified, a null  (i.e.  anonymous)  username  is
          assumed.  The  user  must have atleast ADMIN privileges in order
          for this tool to operate fully.

   -p PASSWORD, --password=PASSWORD
          Specify the password to use when authenticationg with the remote
          host.   If  not  specified,  a null password is assumed. Maximum
          password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

   -P, --password-prompt
          Prompt for password  to  avoid  possibility  of  listing  it  in
          process lists.

   -k K_G, --k-g=K_G
          Specify  the  K_g  BMC  key  to use when authenticating with the
          remote host for IPMI 2.0.  If  not  specified,  a  null  key  is
          assumed. To input the key in hexadecimal form, prefix the string
          with '0x'. E.g., the key 'abc' can be entered  with  the  either
          the string 'abc' or the string '0x616263'

   -K, --k-g-prompt
          Prompt  for  k-g  to  avoid possibility of listing it in process
          lists.

   --session-timeout=MILLISECONDS
          Specify the session timeout in milliseconds. Defaults  to  20000
          milliseconds (20 seconds) if not specified.

   --retransmission-timeout=MILLISECONDS
          Specify  the  packet  retransmission  timeout  in  milliseconds.
          Defaults to 1000 milliseconds (1 second) if not  specified.  The
          retransmission   timeout  cannot  be  larger  than  the  session
          timeout.

   -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
          Specify the IPMI 1.5 authentication type to use.  The  currently
          available  authentication types are NONE, STRAIGHT_PASSWORD_KEY,
          MD2, and MD5. Defaults to MD5 if not specified.

   -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
          Specify the IPMI 2.0 cipher suite ID to use. The Cipher Suite ID
          identifies    a    set   of   authentication,   integrity,   and
          confidentiality algorithms to use for  IPMI  2.0  communication.
          The authentication algorithm identifies the algorithm to use for
          session setup, the integrity algorithm identifies the  algorithm
          to  use  for  session packet signatures, and the confidentiality
          algorithm  identifies  the  algorithm   to   use   for   payload
          encryption.  Defaults to cipher suite ID 3 if not specified. The
          following cipher suite ids are currently supported:

          0 - Authentication Algorithm = None; Integrity Algorithm = None;
          Confidentiality Algorithm = None

          1  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
          None; Confidentiality Algorithm = None

          2 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =
          HMAC-SHA1-96; Confidentiality Algorithm = None

          3  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
          HMAC-SHA1-96; Confidentiality Algorithm = AES-CBC-128

          6 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
          None; Confidentiality Algorithm = None

          7  -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
          HMAC-MD5-128; Confidentiality Algorithm = None

          8 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
          HMAC-MD5-128; Confidentiality Algorithm = AES-CBC-128

          11  - Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
          MD5-128; Confidentiality Algorithm = None

          12 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm  =
          MD5-128; Confidentiality Algorithm = AES-CBC-128

          15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
          = None; Confidentiality Algorithm = None

          16 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
          = HMAC_SHA256_128; Confidentiality Algorithm = None

          17 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
          = HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

   -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
          Specify the privilege level to be used. The currently  available
          privilege  levels  are  USER,  OPERATOR,  and ADMIN. Defaults to
          ADMIN if not specified.

   --config-file=FILE
          Specify an alternate configuration file.

   -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
          Specify  workarounds  to  vendor  compliance  issues.   Multiple
          workarounds  can  be  specified  separated  by commas. A special
          command line flag of "none", will indicate no  workarounds  (may
          be  useful  for overriding configured defaults). See WORKAROUNDS
          below for a list of available workarounds.

   --debug
          Turn on debugging.

   -?, --help
          Output a help list and exit.

   --usage
          Output a usage message and exit.

   -V, --version
          Output the program version and exit.

IPMI-CONFIG OPTIONS

   The following options are used to read, write, and find differences  in
   configuration values.

   -g CATEGORY, --category=CATEGORY
          Specify  the  category  or  categories  of configuration data to
          configure.  Currently available choices: core, chassis, sensors,
          pef,  dcmi. Multiple categories can be separated by comma.  core
          includes all major IPMI configuration necessary to get  IPMI  to
          function on a sytem, such as configuration for users, passwords,
          authentication, networking, and serial-over-lan  (SOL).  chassis
          includes  all  chassis  relevant  configuration  including  boot
          options, front panel buttons, and power behavior. dcmi  includes
          specialized  functions  provided  by  the Data Center Management
          Interface (DCMI). Defaults to core if not specified.

   -o, --checkout
          Fetch configuration information.

   -c, --commit
          Update configuration information  from  a  config  file  or  key
          pairs.

   -d, --diff
          Show differences between stored information and a config file or
          key pairs.

   -n FILENAME, --filename=FILENAME
          Specify a config file  for  checkout/commit/diff.  If  specified
          with   checkout,   cannot   use  with  multiple  hosts  or  with
          --always-prefix.

   -e "KEY=VALUE", --key-pair="KEY=VALUE"
          Specify KEY=VALUE pairs for checkout/commit/diff. Specify KEY by
          SectionName:FieldName.  This  option can be used multiple times.
          On  commit,  any  KEY=VALUE  pairs  will  overwrite  any   pairs
          specified in a file with --filename.

   -S SECTION, --section=SECTION
          Specify a SECTION for checkout. This option can be used multiple
          times. The  SECTION  you  are  specifying  must  be  within  the
          category or categories specified with --category.

   -L, --listsections
          List  available  sections  for  checkout  with  respect  to  the
          category or categories under --category. Some  sections  in  the
          list may not be checked out by default and may require verbosity
          to be increased.

   -v, --verbose
          Output  verbose  information.   When   used   with   --checkout,
          additional uncommon sections and/or fields will be shown. In the
          core category, this includes checking out  Serial  Configuration
          parameters,  Vlan parameters, IPv4 Header parameters, RMCP port,
          and sections for each channel on a system, if multiple  channels
          exist.  In the pef category, this includes checkout out sections
          for each channel on a system, if multiple channels exist.

   -vv    Output very  verbose  information.  Output  additional  detailed
          information about what fields can and cannot be checked out, and
          sometimes the reason  why.  Sometimes  output  fields  that  are
          identified as unsupported on the motherboard.

   --lan-channel-number=NUMBER
          Use   an   specific   channel   number  for  LAN  configuration.
          Particularly  useful  if  motherboard  contains   multiple   LAN
          channels and a user wishes to use a specific one.

   --serial-channel-number=NUMBER
          Use   an  specific  channel  number  for  serial  configuration.
          Particularly useful  if  motherboard  contains  multiple  serial
          channels and a user wishes to use a specific one.

   --sol-channel-number=NUMBER
          Use   an   specific   channel   number  for  SOL  configuration.
          Particularly  useful  if  motherboard  contains   multiple   SOL
          channels and a user wishes to use a specific one.

HOSTRANGED OPTIONS

   The  following  options  manipulate  hostranged  output. See HOSTRANGED
   SUPPORT below for additional information on hostranges.

   -B, --buffer-output
          Buffer hostranged output. For each node, buffer standard  output
          until the node has completed its IPMI operation. When specifying
          this option, data may appear to output slower to the user  since
          the  the entire IPMI operation must complete before any data can
          be  output.   See  HOSTRANGED  SUPPORT  below   for   additional
          information.

   -C, --consolidate-output
          Consolidate hostranged output. The complete standard output from
          every node specified will be consolidated  so  that  nodes  with
          identical  output are not output twice. A header will list those
          nodes  with  the  consolidated  output.  When  this  option   is
          specified,  no  output  can be seen until the IPMI operations to
          all nodes has completed. If the user breaks out of  the  program
          early,  all  currently  consolidated  output will be dumped. See
          HOSTRANGED SUPPORT below for additional information.

   -F NUM, --fanout=NUM
          Specify multiple host fanout. A  "sliding  window"  (or  fanout)
          algorithm is used for parallel IPMI communication so that slower
          nodes or timed out nodes will not impede parallel communication.
          The  maximum  number  of  threads  available at the same time is
          limited by the fanout. The default is 64.

   -E, --eliminate
          Eliminate hosts determined as undetected  by  ipmidetect.   This
          attempts  to  remove  the  common  issue of hostranged execution
          timing out due to several nodes being removed from service in  a
          large  cluster.  The  ipmidetectd  daemon must be running on the
          node executing the command.

   --always-prefix
          Always prefix output, even if only  one  host  is  specified  or
          communicating  in-band.  This  option  is  primarily  useful for
          scripting purposes. Option will be ignored if specified with the
          -C option.

GENERAL USE

   Most users of will want to:

   A)  Run  with --checkout to get a copy of the current configuration and
   store it in a file. The standard output can be redirected to a file  or
   a file can be specified with the --filename option.

   B) Edit the configuration file with an editor.

   C)  Commit  the  configuration  back  using  the  --commit  option  and
   specifying the configuration file  with  the  --filename  option.   The
   configuration  can  be  committed to multiple hosts in parallel via the
   hostrange support.

   Although not typically necessarily,  some  motherboards  do  not  store
   configuration  values  in  non-volatile memory. Therefore, after system
   reboots, some configuration values may have changed. The user may  wish
   to  run configuration tools on each boot to ensure configuration values
   remain.

   Comments will  be  listed  on  occassion  in  checked  out  files  with
   information  on  how  to  configure  fields.   The  ipmi-config.conf(5)
   manpage  also  provides  additional  information  on  the  meaning   of
   different fields.

   For users with large clusters or sets of nodes, you may wish to use the
   same configuration file for all nodes. The one  problem  with  this  is
   that  the  IP address and MAC address will be different on each node in
   your cluster and thus can't be configured through the same config file.
   The  IP  address and MAC address in your config file may be overwritten
   on the command line using  --key-pair  option.  The  following  example
   could  be used in a script to configure each node in a cluster with the
   same BMC config file. The script only needs to determine the correct IP
   address and MAC address to use.

   #     ipmi-config    --commit    -k    Lan_Conf:Ip_Address=$MY_IP    -k
   Lan_Conf:Mac_Address=$MY_MAC --filename=my_bmc.conf

CORE SPECIAL CASE CONFIGURATION INFORMATION

   The UserN:Password fields (where N is a number) cannot be  checked  out
   on some systems, therefore the checked out value will always be blank.

   The UserN:Enable_User field (where N is a number) cannot be checked out
   on older IPMI systems, therefore the checked out value will sometime be
   blank.

   The   UserN:Lan_Session_Limit   and  UserN:Serial_Session_Limit  fields
   (where N is a number) cannot be checked out on some systems,  therefore
   the  checked  out value will always be blank. If not specified in later
   commits of configurations, the field  may  be  reset  to  0  due  to  a
   requirement that other fields (configured along with the session limit)
   will require  an  input  value  for  the  session  limit.   Under  most
   conditions,  it  is  not necessary to set this field and most users may
   choose to  ignore  it.  This  field  is  considered  optional  by  IPMI
   standards,  and may result in errors when attempting to configure it to
   a non-zero value. If errors to occur,  setting  the  value  back  to  0
   should resolve problems.

   The  fields  Lan_Conf:IP_Address  and  Lan_Conf:MAC_Address  cannot  be
   committed in parallel via  hostrange  support.  Each  machine  must  be
   configured with a unique IP Address and MAC Address tuple, therefore we
   disallow this configuration in ipmi-config.

   On some motherboards, Lan_Conf:MAC_Address may be read only and the MAC
   address is automatically configured.

   On some motherboards, Lan_Conf:MAC_Address may be read only and the MAC
   address is configured via an OEM command. See ipmi-oem(8) to see if OEM
   configuration for your motherboard is supported.

   On  some  motherboards, a number of user configuration fields cannot be
   read or configured until after a non-null username or non-null password
   is  configured.  In  some  of these cases, an appropriate output in the
   config file will indicate this situation. However, not all  motherboard
   corner  cases  may  be detected. Users may wish to play around with the
   ordering of fields to work around these problems.

   On some motherboards, OEM Authentication  in  Lan_Conf_Auth  cannot  be
   enabled.  However,  the  default motherboard settings have these fields
   enabled. Users are advised to disable all OEM  Authentication  in  this
   section.

   On  some  motherboards,  multiple  channels may exist for either LAN or
   Serial IPMI communication. If multiple channels exist, configuration of
   both  channels  can  be  viewed  and  ultimately  configured by running
   --checkout under verbose  mode.  Each  section  or  key  name  will  be
   suffixed  appropriately  with  the word Channel and the channel number.
   For example, you might see a Lan_Conf_Channel_1 and Lan_Conf_Channel_3,
   where  you  can  configure  LAN  configuration  on  Channels  1  and  3
   respectively.

   On some motherboards, configuration changes will not be  "absorbed"  by
   the   system   until   the  motherboard  is  hard-reset.  This  can  be
   accomplished by physically powering off and on the system (e.g.  button
   push), or it can be accomplished through a cold-reset. A cold-reset can
   be executed via bmc-device.

CHASSIS SPECIAL CASE CONFIGURATION INFORMATION

   The
   Chassis_Front_Panel_Buttons:Enable_Standby_Button_For_Entering_Standy,
   Chassis_Front_Panel_Buttons:Enable_Diagnostic_Interrupt_Button
   Chassis_Front_Panel_Buttons:Enable_Reset_Button,                    and
   Chassis_Front_Panel_Buttons:Enable_Power_Off_Button_For_Power_Off_Only
   fields  may  not  be  able  to  be  checked  out  on some IPMI systems,
   therefore the checked out value may be blank. Some of these fields  may
   be       disableable,      while      some      are      not.       The
   Chassis_Power_Conf:Power_Control_Interval field cannot be checked  out.
   Therefore the checked out value will always be blank.

PEF SPECIAL CASE CONFIGURATION INFORMATION

   On  some  motherboards,  multiple  channels  may  exist  for  LAN  IPMI
   communication.  If  multiple  channels  exist,  configuration  of  both
   channels  can be viewed and ultimately configured by running --checkout
   under verbose mode. Each section name will  be  suffixed  appropriately
   with  the  word  Channel and the channel number. For example, you might
   see a Community_String_Channel_1 and Community_String_Channel_3,  where
   you   can   configure   the  Community  String  on  Channels  1  and  3
   respectively.  The following are the options  suitable  for  input  for
   Sensor_Type in PEF configuration.

   Sensor_Type Options
          Reserved, Temperature, Voltage, Current, Fan, Physical_Security,
          Platform_Security_Violation_Attempt,  Processor,   Power_Supply,
          Power_Unit,  Cooling_Device,  Other_Units_Based_Sensor,  Memory,
          Drive_Slot,    Post_Memory_Resize,     System_Firmware_Progress,
          Event_Logging_Disabled,         Watchdog1,         System_Event,
          Critical_Interrupt,         Button_Switch,         Module_Board,
          Microcontroller_Coprocessor,   Add_In_Card,  Chassis,  Chip_Set,
          Other_FRU,            Cable_Interconnect,            Terminator,
          System_Boot_Initiated,  Boot_Error,  OS_Boot,  OS_Critical_Stop,
          Slot_Connector,       System_ACPI_Power_State,        Watchdog2,
          Platform_Alert,     Entity_Presence,    Monitor_Asic_IC,    Lan,
          Management_Subsystem_Health,       Battery,       Session_Audit,
          Version_Change, FRU_State, and Any

SENSORS SPECIAL CASE CONFIGURATION INFORMATION

   Since    many    configurable    fields    involve   decimal   numbers,
   precision/floating point inaccuracies may occur  when  configuring  new
   thresholds.  The  inaccuracies  may  not be apparent immediately. It is
   recommend users verify their changes after configuring new thresholds.

HOSTRANGED SUPPORT

   Multiple hosts can be input either as an explicit comma separated lists
   of  hosts  or  a  range of hostnames in the general form: prefix[n-m,l-
   k,...], where n < m and l < k,  etc.  The  later  form  should  not  be
   confused  with  regular  expression  character classes (also denoted by
   []). For example, foo[19] does not represent foo1 or foo9,  but  rather
   represents a degenerate range: foo19.

   This  range  syntax  is  meant only as a convenience on clusters with a
   prefixNN naming convention and specification of ranges  should  not  be
   considered  necessary -- the list foo1,foo9 could be specified as such,
   or by the range foo[1,9].

   Some examples of range usage follow:
       foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
       foo[7,9-10] instead of foo7,foo9,foo10
       foo[0-3] instead of foo0,foo1,foo2,foo3

   As a reminder to the reader, some shells will interpret brackets ([ and
   ])  for  pattern matching. Depending on your shell, it may be necessary
   to enclose ranged lists within quotes.

   When multiple hosts are  specified  by  the  user,  a  thread  will  be
   executed  for  each host in parallel up to the configured fanout (which
   can be adjusted via the -F option). This will  allow  communication  to
   large numbers of nodes far more quickly than if done in serial.

   By  default,  standard  output  from each node specified will be output
   with the hostname prepended to  each  line.  Although  this  output  is
   readable  in  many  situations,  it  may  be difficult to read in other
   situations. For example,  output  from  multiple  nodes  may  be  mixed
   together. The -B and -C options can be used to change this default.

   In-band  IPMI  Communication  will be used when the host "localhost" is
   specified.  This  allows  the  user  to  add  the  localhost  into  the
   hostranged output.

GENERAL TROUBLESHOOTING

   Most often, IPMI problems are due to configuration problems.

   IPMI  over  LAN  problems  involve  a  misconfiguration  of  the remote
   machine's BMC.  Double check to make sure the following are  configured
   properly  in  the remote machine's BMC: IP address, MAC address, subnet
   mask,  username,  user  enablement,  user  privilege,   password,   LAN
   privilege, LAN enablement, and allowed authentication type(s). For IPMI
   2.0  connections,  double  check  to  make  sure   the   cipher   suite
   privilege(s)  and  K_g  key are configured properly. The ipmi-config(8)
   tool can be used to check and/or change these configuration settings.

   Inband IPMI problems are  typically  caused  by  improperly  configured
   drivers or non-standard BMCs.

   In  addition  to the troubleshooting tips below, please see WORKAROUNDS
   below to also if there are any vendor  specific  bugs  that  have  been
   discovered and worked around.

   Listed  below  are  many  of the common issues for error messages.  For
   additional support, please e-mail the <freeipmi-users@gnu.org>  mailing
   list.

   "username  invalid"  - The username entered (or a NULL username if none
   was entered) is not available on the remote machine.  It  may  also  be
   possible the remote BMC's username configuration is incorrect.

   "password  invalid"  - The password entered (or a NULL password if none
   was entered) is not correct. It may also be possible the  password  for
   the user is not correctly configured on the remote BMC.

   "password  verification timeout" - Password verification has timed out.
   A "password invalid" error (described  above)  or  a  generic  "session
   timeout" (described below) occurred.  During this point in the protocol
   it cannot be differentiated which occurred.

   "k_g invalid" - The K_g key entered (or a NULL  K_g  key  if  none  was
   entered)  is  not  correct.  It may also be possible the K_g key is not
   correctly configured on the remote BMC.

   "privilege level insufficient" - An IPMI command requires a higher user
   privilege  than  the one authenticated with. Please try to authenticate
   with a higher privilege. This may require authenticating to a different
   user which has a higher maximum privilege.

   "privilege  level  cannot  be  obtained  for this user" - The privilege
   level you are attempting  to  authenticate  with  is  higher  than  the
   maximum allowed for this user. Please try again with a lower privilege.
   It may also be possible the maximum privilege level allowed for a  user
   is not configured properly on the remote BMC.

   "authentication  type  unavailable for attempted privilege level" - The
   authentication type you wish to authenticate with is not available  for
   this privilege level. Please try again with an alternate authentication
   type or  alternate  privilege  level.  It  may  also  be  possible  the
   available  authentication  types  you  can  authenticate  with  are not
   correctly configured on the remote BMC.

   "cipher suite id unavailable"  -  The  cipher  suite  id  you  wish  to
   authenticate  with is not available on the remote BMC. Please try again
   with an alternate  cipher  suite  id.  It  may  also  be  possible  the
   available  cipher  suite ids are not correctly configured on the remote
   BMC.

   "ipmi 2.0 unavailable" - IPMI 2.0 was  not  discovered  on  the  remote
   machine. Please try to use IPMI 1.5 instead.

   "connection  timeout"  - Initial IPMI communication failed. A number of
   potential errors are possible, including an invalid hostname specified,
   an  IPMI  IP  address  cannot  be  resolved, IPMI is not enabled on the
   remote server, the  network  connection  is  bad,  etc.  Please  verify
   configuration and connectivity.

   "session  timeout"  - The IPMI session has timed out. Please reconnect.
   If this error occurs often, you may wish to increase the retransmission
   timeout. Some remote BMCs are considerably slower than others.

   "device  not  found"  - The specified device could not be found. Please
   check configuration or inputs and try again.

   "driver timeout" - Communication with the driver or  device  has  timed
   out. Please try again.

   "message  timeout"  - Communication with the driver or device has timed
   out. Please try again.

   "BMC  busy"  -  The  BMC  is  currently  busy.  It  may  be  processing
   information  or  have  too many simultaneous sessions to manage. Please
   wait and try again.

   "could not find inband device" - An inband device could not  be  found.
   Please  check configuration or specify specific device or driver on the
   command line.

   "driver timeout" - The inband driver has timed out communicating to the
   local  BMC  or  service  processor. The BMC or service processor may be
   busy or (worst case) possibly non-functioning.

WORKAROUNDS

   With so many different vendors implementing their own  IPMI  solutions,
   different  vendors  may implement their IPMI protocols incorrectly. The
   following describes a number  of  workarounds  currently  available  to
   handle  discovered  compliance  issues. When possible, workarounds have
   been implemented so they will be transparent to the user. However, some
   will  require  the  user  to  specify  a  workaround be used via the -W
   option.

   The hardware listed below may only indicate the hardware that a problem
   was  discovered  on.  Newer  versions  of hardware may fix the problems
   indicated below. Similar machines from vendors may or may  not  exhibit
   the  same  problems.  Different vendors may license their firmware from
   the same IPMI firmware developer,  so  it  may  be  worthwhile  to  try
   workarounds listed below even if your motherboard is not listed.

   If  you  believe  your hardware has an additional compliance issue that
   needs a workaround to  be  implemented,  please  contact  the  FreeIPMI
   maintainers on <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

   assumeio   -   This  workaround  flag  will  assume  inband  interfaces
   communicate with system I/O rather than being memory-mapped. This  will
   work  around  systems that report invalid base addresses. Those hitting
   this issue may see "device not supported" or  "could  not  find  inband
   device" errors.  Issue observed on HP ProLiant DL145 G1.

   spinpoll  -  This workaround flag will inform some inband drivers (most
   notably the KCS driver) to spin while polling rather than  putting  the
   process to sleep. This may significantly improve the wall clock running
   time of tools because an operating system scheduler's  granularity  may
   be  much larger than the time it takes to perform a single IPMI message
   transaction. However, by spinning, your system may be  performing  less
   useful work by not contexting out the tool for a more useful task.

   authcap  -  This  workaround  flag  will skip early checks for username
   capabilities, authentication capabilities, and K_g  support  and  allow
   IPMI  authentication  to  succeed.  It  works around multiple issues in
   which the remote system does not properly report username capabilities,
   authentication  capabilities,  or  K_g status. Those hitting this issue
   may  see  "username  invalid",  "authentication  type  unavailable  for
   attempted privilege level", or "k_g invalid" errors.  Issue observed on
   Asus  P5M2/P5MT-R/RS162-E4/RX4,  Intel  SR1520ML/X38ML,  and  Sun  Fire
   2200/4150/4450 with ELOM.

   nochecksumcheck  - This workaround flag will tell FreeIPMI to not check
   the checksums returned from IPMI command  responses.  It  works  around
   systems that return invalid checksums due to implementation errors, but
   the packet is otherwise valid. Users are cautioned on the use  of  this
   option,  as  it  removes  validation of packet integrity in a number of
   circumstances.  However,  it  is  unlikely  to  be  an  issue  in  most
   situations.  Those  hitting  this  issue  may see "connection timeout",
   "session timeout", or "password verification timeout" errors.  On  IPMI
   1.5  connections, the "noauthcodecheck" workaround may also needed too.
   Issue  observed  on  Supermicro  X9SCM-iiF,  Supermicro  X9DRi-F,   and
   Supermicro X9DRFR.

   idzero  -  This  workaround  flag  will  allow  empty session IDs to be
   accepted by the client. It works around IPMI sessions that report empty
   session  IDs  to  the client. Those hitting this issue may see "session
   timeout" errors. Issue observed on Tyan S2882 with M3289 BMC.

   unexpectedauth - This workaround flag will  allow  unexpected  non-null
   authcodes  to  be checked as though they were expected. It works around
   an issue when packets contain non-null authentication  data  when  they
   should  be  null  due  to  disabled  per-message  authentication. Those
   hitting this issue may see "session timeout" errors. Issue observed  on
   Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

   forcepermsg   -   This   workaround   flag   will   force   per-message
   authentication to be used no matter what is advertised  by  the  remote
   system.  It  works  around  an issue when per-message authentication is
   advertised as disabled  on  the  remote  system,  but  it  is  actually
   required  for  the  protocol. Those hitting this issue may see "session
   timeout" errors.  Issue observed on IBM eServer 325.

   endianseq - This workaround flag will flip the endian  of  the  session
   sequence  numbers  to  allow the session to continue properly. It works
   around IPMI 1.5 session sequence numbers that  are  the  wrong  endian.
   Those  hitting  this  issue  may  see  "session  timeout" errors. Issue
   observed on  some  Sun  ILOM  1.0/2.0  (depends  on  service  processor
   endian).

   noauthcodecheck  - This workaround flag will tell FreeIPMI to not check
   the authentication codes returned from IPMI 1.5 command  responses.  It
   works  around  systems  that return invalid authentication codes due to
   hashing or implementation errors. Users are cautioned  on  the  use  of
   this  option,  as  it  removes  an  authentication  check verifying the
   validity of a packet. However, in most organizations, this is  unlikely
   to  be  a  security issue. Those hitting this issue may see "connection
   timeout", "session timeout", or "password verification timeout" errors.
   Issue   observed   on   Xyratex   FB-H8-SRAY,  Intel  Windmill,  Quanta
   Winterfell, and Wiwynn Windmill.

   intel20 - This workaround flag will work around several Intel IPMI  2.0
   authentication issues. The issues covered include padding of usernames,
   and password  truncation  if  the  authentication  algorithm  is  HMAC-
   MD5-128. Those hitting this issue may see "username invalid", "password
   invalid", or "k_g invalid" errors. Issue observed  on  Intel  SE7520AF2
   with Intel Server Management Module (Professional Edition).

   supermicro20 - This workaround flag will work around several Supermicro
   IPMI 2.0  authentication  issues  on  motherboards  w/  Peppercon  IPMI
   firmware.   The   issues   covered   include  handling  invalid  length
   authentication codes.  Those  hitting  this  issue  may  see  "password
   invalid"  errors.   Issue  observed  on  Supermicro  H8QME  with  SIMSO
   daughter card. Confirmed fixed on newerver firmware.

   sun20 - This workaround flag will work work around several Sun IPMI 2.0
   authentication issues. The issues covered include invalid lengthed hash
   keys, improperly hashed keys, and invalid cipher suite  records.  Those
   hitting  this  issue  may see "password invalid" or "bmc error" errors.
   Issue observed on Sun Fire 4100/4200/4500 with ILOM.   This  workaround
   automatically includes the "opensesspriv" workaround.

   opensesspriv - This workaround flag will slightly alter FreeIPMI's IPMI
   2.0 connection protocol to workaround an invalid hashing algorithm used
   by  the remote system. The privilege level sent during the Open Session
   stage of an IPMI 2.0 connection is used for hashing keys instead of the
   privilege  level  sent during the RAKP1 connection stage. Those hitting
   this issue may see "password invalid", "k_g invalid", or "bad  rmcpplus
   status  code"  errors.   Issue observed on Sun Fire 4100/4200/4500 with
   ILOM, Inventec 5441/Dell Xanadu II, Supermicro X8DTH, Supermicro X8DTG,
   Intel S5500WBV/Penguin Relion 700, Intel S2600JF/Appro 512X, and Quanta
   QSSC-S4R/Appro GB812X-CN. This workaround  is  automatically  triggered
   with the "sun20" workaround.

   integritycheckvalue  - This workaround flag will work around an invalid
   integrity check value during an IPMI  2.0  session  establishment  when
   using  Cipher Suite ID 0. The integrity check value should be 0 length,
   however the remote motherboard responds with a non-empty  field.  Those
   hitting  this  issue  may  see  "k_g invalid" errors. Issue observed on
   Supermicro X8DTG, Supermicro X8DTU, and Intel  S5500WBV/Penguin  Relion
   700, and Intel S2600JF/Appro 512X.

   No IPMI 1.5 Support - Some motherboards that support IPMI 2.0 have been
   found to not support IPMI 1.5. Those hitting this issue may  see  "ipmi
   2.0  unavailable"  or  "connection  timeout"  errors. This issue can be
   worked around by using IPMI 2.0  instead  of  IPMI  1.5  by  specifying
   --driver-type=LAN_2_0. Issue observed on HP Proliant DL 145.

   slowcommit  -  This  workaround  will  slow  down commits to the BMC by
   sleeping one second between the commit of  sections.  It  works  around
   motherboards  that have BMCs that can be overwhelmed by commits.  Those
   hitting this issue may see commit errors or commits not  being  written
   to the BMC. Issue observed on Supermicro H8QME.

   veryslowcommit  -  This workaround will slow down commits to the BMC by
   sleeping one second between the commit of every key.  It  works  around
   motherboards  that have BMCs that can be overwhelmed by commits.  Those
   hitting this issue may see commit errors or commits not  being  written
   to the BMC. Issue observed on Quanta S99Q/Dell FS12-TY.

   solchannelassumelanchannel  - This workaround will force ipmi-config to
   assume that the channel used SOL is identical to the channel  used  for
   LAN.  On  some  motherboards,  the SOL channel is reported incorrectly,
   leading to incorrect configuration. Most notably, this problem has come
   up  when  attempting to configure multiple channels.  Issue observed on
   Intel S5500WBV/Penguin Relion 700.

EXAMPLES

   # ipmi-config --checkout

   Output all core configuration information  to  the  console.   #  ipmi-
   config --checkout --category=pef

   Output all pef configuration information to the console.  # ipmi-config
   --checkout --category=pef,chassis

   Output all pef and chassis configuration information to the console.

   # ipmi-config --checkout --filename=bmc-data1.conf

   Store all core configuration information in bmc-data1.conf.

   # ipmi-config --diff --filename=bmc-data2.conf

   Show all difference between the  current  configuration  and  the  bmc-
   data2.conf file.

   #                ipmi-config                --diff               --key-
   pair="lan_conf_misc:gratuitous_arp_interval=8"

   Show   difference   with   the   current    configuration    and    the
   'lan_conf_misc:gratuitous_arp_interval' of value '8'.

   # ipmi-config --commit --filename=bmc-data1.conf

   Commit all configuration values from the bmc-data1.conf file.

   #               ipmi-config               --commit               --key-
   pair="lan_conf_misc:gratuitous_arp_interval=4"

   Commit key 'lan_conf_misc:gratuitous_arp_interval' of value '4'.

   #    ipmi-config    --commit    --filename=bmc-data-updt.conf    --key-
   pair="lan_conf_misc:gratuitous_arp_interval=4"

   Commit   all  configuration  values  from  bmc-data-updt.conf  and  key
   'lan_conf_misc:gratuitous_arp_interval' of value '4'.

DIAGNOSTICS

   Upon successful execution, exit status is 0. On non-fatal  error,  exit
   status is 1. On fatal error, exit status is 2.

   If multiple hosts are specified for communication, the exit status is 0
   if and only if all targets successfully execute. If any non-fatal error
   occurs, exit status is 1. If any fatal error occurs, exit status is 2.

KNOWN ISSUES

   On  older  operating systems, if you input your username, password, and
   other potentially security relevant information on  the  command  line,
   this information may be discovered by other users when using tools like
   the ps(1) command or looking in the /proc file system. It is  generally
   more  secure  to input password information with options like the -P or
   -K options. Configuring security relevant information in  the  FreeIPMI
   configuration  file  would  also  be  an  appropriate  way to hide this
   information.

   In order to prevent brute force attacks,  some  BMCs  will  temporarily
   "lock  up" after a number of remote authentication errors. You may need
   to wait awhile in order to this temporary "lock up" to pass before  you
   may authenticate again.

REPORTING BUGS

   Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT

   Copyright © 2003-2014 FreeIPMI Core Team.

   This program is free software; you can redistribute it and/or modify it
   under the terms of the GNU General Public License as published  by  the
   Free  Software Foundation; either version 3 of the License, or (at your
   option) any later version.

SEE ALSO

   ipmi-config.conf(5), freeipmi(7), bmc-device(8)

   http://www.gnu.org/software/freeipmi/





Opportunity


Personal Opportunity - Free software gives you access to billions of dollars of software at no cost. Use this software for your business, personal use or to develop a profitable skill. Access to source code provides access to a level of capabilities/information that companies protect though copyrights. Open source is a core component of the Internet and it is available to you. Leverage the billions of dollars in resources and capabilities to build a career, establish a business or change the world. The potential is endless for those who understand the opportunity.

Business Opportunity - Goldman Sachs, IBM and countless large corporations are leveraging open source to reduce costs, develop products and increase their bottom lines. Learn what these companies know about open source and how open source can give you the advantage.





Free Software


Free Software provides computer programs and capabilities at no cost but more importantly, it provides the freedom to run, edit, contribute to, and share the software. The importance of free software is a matter of access, not price. Software at no cost is a benefit but ownership rights to the software and source code is far more significant.


Free Office Software - The Libre Office suite provides top desktop productivity tools for free. This includes, a word processor, spreadsheet, presentation engine, drawing and flowcharting, database and math applications. Libre Office is available for Linux or Windows.





Free Books


The Free Books Library is a collection of thousands of the most popular public domain books in an online readable format. The collection includes great classical literature and more recent works where the U.S. copyright has expired. These books are yours to read and use without restrictions.


Source Code - Want to change a program or know how it works? Open Source provides the source code for its programs so that anyone can use, modify or learn how to write those programs themselves. Visit the GNU source code repositories to download the source.





Education


Study at Harvard, Stanford or MIT - Open edX provides free online courses from Harvard, MIT, Columbia, UC Berkeley and other top Universities. Hundreds of courses for almost all major subjects and course levels. Open edx also offers some paid courses and selected certifications.


Linux Manual Pages - A man or manual page is a form of software documentation found on Linux/Unix operating systems. Topics covered include computer programs (including library and system calls), formal standards and conventions, and even abstract concepts.