ipmi-sel(8)


NAME

   ipmi-sel - display SEL entries

SYNOPSIS

   ipmi-sel [OPTION...]

DESCRIPTION

   Ipmi-sel is used to view and manage System Event Log (SEL) entries. SEL
   records store system event information and may be useful for  debugging
   problems.    Ipmi-sel   does  not  inform  the  user  if  an  event  is
   particularly good or bad, just that the event occurred. Users may  wish
   to use the --output-event-state option to output the analyzed state.

   Listed  below  are general IPMI options, tool specific options, trouble
   shooting  information,  workaround  information,  examples,  and  known
   issues.  For a general introduction to FreeIPMI please see freeipmi(7).
   To perform some advanced SEL management, please see bmc-device(8).

GENERAL OPTIONS

   The  following  options  are  general  options  for  configuring   IPMI
   communication and executing general tool commands.

   -D IPMIDRIVER, --driver-type=IPMIDRIVER
          Specify  the  driver  type  to  use  instead  of  doing  an auto
          selection.  The currently available outofband  drivers  are  LAN
          and  LAN_2_0,  which perform IPMI 1.5 and IPMI 2.0 respectively.
          The currently available inband drivers are KCS, SSIF,  OPENIPMI,
          SUNBMC, and INTELDCMI.

   --disable-auto-probe
          Do not probe in-band IPMI devices for default settings.

   --driver-address=DRIVER-ADDRESS
          Specify  the  in-band  driver  address to be used instead of the
          probed value. DRIVER-ADDRESS should be prefixed with "0x" for  a
          hex value and '0' for an octal value.

   --driver-device=DEVICE
          Specify the in-band driver device path to be used instead of the
          probed path.

   --register-spacing=REGISTER-SPACING
          Specify the in-band  driver  register  spacing  instead  of  the
          probed  value. Argument is in bytes (i.e. 32bit register spacing
          = 4)

   --target-channel-number=CHANNEL-NUMBER
          Specify the in-band driver target channel number  to  send  IPMI
          requests to.

   --target-slave-address=SLAVE-ADDRESS
          Specify  the  in-band  driver  target  slave number to send IPMI
          requests to.

   -h                                             IPMIHOST1,IPMIHOST2,...,
   --hostname=IPMIHOST1[:PORT],IPMIHOST2[:PORT],...
          Specify   the  remote  host(s)  to  communicate  with.  Multiple
          hostnames may be separated by comma or may  be  specified  in  a
          range format; see HOSTRANGED SUPPORT below. An optional port can
          be specified with  each  host,  which  may  be  useful  in  port
          forwarding or similar situations.

   -u USERNAME, --username=USERNAME
          Specify  the username to use when authenticating with the remote
          host.  If not specified, a null  (i.e.  anonymous)  username  is
          assumed. The user must have atleast USER privileges in order for
          this tool to operate fully.

   -p PASSWORD, --password=PASSWORD
          Specify the password to use when authenticationg with the remote
          host.   If  not  specified,  a null password is assumed. Maximum
          password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.

   -P, --password-prompt
          Prompt for password  to  avoid  possibility  of  listing  it  in
          process lists.

   -k K_G, --k-g=K_G
          Specify  the  K_g  BMC  key  to use when authenticating with the
          remote host for IPMI 2.0.  If  not  specified,  a  null  key  is
          assumed. To input the key in hexadecimal form, prefix the string
          with '0x'. E.g., the key 'abc' can be entered  with  the  either
          the string 'abc' or the string '0x616263'

   -K, --k-g-prompt
          Prompt  for  k-g  to  avoid possibility of listing it in process
          lists.

   --session-timeout=MILLISECONDS
          Specify the session timeout in milliseconds. Defaults  to  20000
          milliseconds (20 seconds) if not specified.

   --retransmission-timeout=MILLISECONDS
          Specify  the  packet  retransmission  timeout  in  milliseconds.
          Defaults to 1000 milliseconds (1 second) if not  specified.  The
          retransmission   timeout  cannot  be  larger  than  the  session
          timeout.

   -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
          Specify the IPMI 1.5 authentication type to use.  The  currently
          available  authentication types are NONE, STRAIGHT_PASSWORD_KEY,
          MD2, and MD5. Defaults to MD5 if not specified.

   -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
          Specify the IPMI 2.0 cipher suite ID to use. The Cipher Suite ID
          identifies    a    set   of   authentication,   integrity,   and
          confidentiality algorithms to use for  IPMI  2.0  communication.
          The authentication algorithm identifies the algorithm to use for
          session setup, the integrity algorithm identifies the  algorithm
          to  use  for  session packet signatures, and the confidentiality
          algorithm  identifies  the  algorithm   to   use   for   payload
          encryption.  Defaults to cipher suite ID 3 if not specified. The
          following cipher suite ids are currently supported:

          0 - Authentication Algorithm = None; Integrity Algorithm = None;
          Confidentiality Algorithm = None

          1  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
          None; Confidentiality Algorithm = None

          2 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =
          HMAC-SHA1-96; Confidentiality Algorithm = None

          3  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
          HMAC-SHA1-96; Confidentiality Algorithm = AES-CBC-128

          6 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
          None; Confidentiality Algorithm = None

          7  -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
          HMAC-MD5-128; Confidentiality Algorithm = None

          8 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
          HMAC-MD5-128; Confidentiality Algorithm = AES-CBC-128

          11  - Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
          MD5-128; Confidentiality Algorithm = None

          12 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm  =
          MD5-128; Confidentiality Algorithm = AES-CBC-128

          15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
          = None; Confidentiality Algorithm = None

          16 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
          = HMAC_SHA256_128; Confidentiality Algorithm = None

          17 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
          = HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128

   -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
          Specify the privilege level to be used. The currently  available
          privilege  levels  are  USER,  OPERATOR,  and ADMIN. Defaults to
          OPERATOR if not specified.

   --config-file=FILE
          Specify an alternate configuration file.

   -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
          Specify  workarounds  to  vendor  compliance  issues.   Multiple
          workarounds  can  be  specified  separated  by commas. A special
          command line flag of "none", will indicate no  workarounds  (may
          be  useful  for overriding configured defaults). See WORKAROUNDS
          below for a list of available workarounds.

   --debug
          Turn on debugging.

   -?, --help
          Output a help list and exit.

   --usage
          Output a usage message and exit.

   -V, --version
          Output the program version and exit.

IPMI-SEL OPTIONS

   The following options are specific to Ipmi-sel.

   -v     Output verbose output. This option will output event  direction.
          Event  direction may be useful to differentiate severity between
          some events. For example, some motherboards may issue  an  event
          both  when  a  temperature  exceeds a threshold and when it goes
          back down below it.

   -vv    Output very verbose output. This option will  output  additional
          information  than  verbose  output.  Most notably it will output
          additional hex codes  to  given  information  on  ambiguous  SEL
          entries,  such  as  OEM  codes.  For  example,  it  will  output
          Generator ID hex codes for sensors  without  names,  event  type
          codes  for  OEM  events,  and record types for OEM records. This
          information may be useful if you are writing a parser outside of
          ipmi-sel to interpret OEM information.

   -i, --info
          Show general information about the SEL.

   --display=RECORD-IDS-LIST
          Display  SEL  records  by  record  id.  Accepts  space  or comma
          separated lists.

   --exclude-display=RECORD-IDS-LIST
          Exclude display of SEL records by record id.  Accepts  space  or
          comma separated lists.

   --display-range=START-END
          Display SEL records from record id START to END.

   --exclude-display-range=START-END
          Exclude display of SEL records from record id START to END.

   --date-range=DATE-DATE
          Display  SEL records with events occurring in the specified date
          range.  Dates may  be  specified  in  MM/DD/YYYY  or  MM-DD-YYYY
          format.  The  month  may  be  specified  as  a  numeral  or  its
          abbreviated string name. The current local system  time  can  be
          specified with "now". Note that non-timestamped records will not
          be  displayed  automatically  because  they  do  not  possess  a
          timestamp.

   --exclude-date-range=DATE-DATE
          Exclude  display  of  SEL  records  with events occurring in the
          specified date range. Dates may be specified  in  MM/DD/YYYY  or
          MM-DD-YYYY  format.  The  month may be specified as a numeral or
          its abbreviated string name. The current local system  time  can
          be  specified with "now". Note that non-timestamped records will
          be  displayed  automatically  because  they  do  not  possess  a
          timestamp.

   -t SENSOR-TYPE-LIST, --sensor-types=SENSOR-TYPE-LIST
          Specify  sensor types to show SEL events for. Multiple types can
          be separated by commas or spaces. A special command line type of
          "all",  will  indicate  all types should be shown (may be useful
          for overriding configured defaults). Users  may  specify  sensor
          types  by  string  (see  --list-sensor-types below) or by number
          (decimal or hex).

   -T SENSOR-TYPE-LIST, --exclude-sensor-types=SENSOR-TYPE-LIST
          Specify sensor types to not show SEL events for. Multiple  types
          can  be  separated  by  commas or spaces. A special command line
          type of "none", will indicate no types should be  excluded  (may
          be useful for overriding configured defaults). Users may specify
          sensor types by string (see  --list-sensor-types  below)  or  by
          number (decimal or hex).

   -L, --list-sensor-types
          List sensor types.

   --tail=count
          Display  approximately  the  last count SEL records. The display
          count is calculated by approximating the record ids of the  last
          SEL   records.  It's  correctness  depends  highly  on  the  SEL
          implementation by the vendor.

   --clear
          Clear SEL.

   --post-clear
          Identical to --clear, except the SEL clearning will be performed
          after SEL event records are displayed. This option is useful for
          scripting if users intend to log SEL events to another log, then
          immediately   clear  SEL.  Unlike  calling  --clear  in  another
          execution of ipmi-sel, this option will use SEL reservations  to
          notify  the  user  if a SEL change has occurred while displaying
          and clearing the SEL. This can protect users from a race,  where
          a  new  SEL  event  is unknowingly generated before clearing the
          SEL. Note that SEL reservations are  optionally  implemented  by
          vendors and may not be available on all machines.

   --delete=RECORD-IDS-LIST
          Delete  records  by record id in the SEL. Accepts space or comma
          separated lists.

   --delete-range=START-END
          Delete record ids from START to END in the SEL.

   --system-event-only
          Output  only  system  event  records  (i.e.  don't  output   OEM
          records).

   --oem-event-only
          Output  only  OEM  event records (i.e. don't output system event
          records).

   --output-manufacturer-id
          For OEM SEL record types, output the manufacturer ID along  with
          event data when available.

   --output-event-state
          Output event state in output. This will add an additional output
          reporting if an event should be viewed as NOMINAL,  WARNING,  or
          CRITICAL.   The event state is an interpreted value based on the
          configuration  file   /etc/freeipmi//freeipmi_interpret_sel.conf
          and the event direction.  See freeipmi_interpret_sel.conf(5) for
          more information.

   --event-state-config-file=FILE
          Specify an alternate  event  state  configuration  file.  Option
          ignored if --output-event-state not specified.

   --hex-dump
          Hex-dump SEL entries.

   --interpret-oem-data
          Attempt  to  interpret  OEM  data,  such  as  event data, sensor
          readings, or general extra info, etc. If an  OEM  interpretation
          is   not  available,  the  default  output  will  be  generated.
          Correctness of OEM interpretations cannot be guaranteed  due  to
          potential  changes  OEM  vendors may make in products, firmware,
          etc.  See  OEM  INTERPRETATION  below  for  confirmed  supported
          motherboard interpretations.

   --output-oem-event-strings
          Some motherboards support an IPMI OEM extension that returns the
          string output for a system event.  Such  string  output  may  be
          beneficial  for  determining  the  meaning  behind  OEM specific
          events. This option will use the OEM event  string  to  describe
          all  system  events  in the ipmi-sel output. This option differs
          from --interpret-oem-data option in that all system events  will
          output  the  vendor  supplied event string, not just events that
          are OEM specific. The event string may be  very  different  from
          the normal FreeIPMI event string output. If an OEM event strings
          is not available, the  default  output  will  be  output.   This
          option  is  confirmed  to  work  for Fujitsu iRMC S1 and iRMC S2
          systems.

   --entity-sensor-names
          Output sensor names prefixed with their entity id  and  instance
          number   when   appropriate.  This  may  be  necessary  on  some
          motherboards to help identify what sensors are referencing.  For
          example,  a  motherboard may have multiple sensors named 'TEMP'.
          The entity id and instance number may help clarify which  sensor
          refers to "Processor 1" vs. "Processor 2".

   --no-sensor-type-output
          Do  not show sensor type output for each entry. On many systems,
          the sensor type is redundant to the name of the sensor. This can
          especially  be  true  if --entity-sensor-names is specified.  If
          the sensor name is sufficient, or if the sensor type  is  of  no
          interest  to  the user, this option can be specified to condense
          output.

   --comma-separated-output
          Output fields in comma separated format.

   --no-header-output
          Do not output column headers. May be useful in scripting.

   --non-abbreviated-units
          Output non-abbreviated units (e.g. 'Amps' instead of  'A').  May
          aid  in  disambiguation  of  units  (e.g.  'C'  for  Celsius  or
          Coulombs).

   --legacy-output
          Output in legacy format. Newer options may not be applicable  to
          legacy output.

SDR CACHE OPTIONS

   This tool requires access to the sensor data repository (SDR) cache for
   general operation. By default, SDR data will be downloaded  and  cached
   on the local machine. The following options apply to the SDR cache.

   -f, --flush-cache
          Flush  a  cached  version  of  the  sensor data repository (SDR)
          cache. The SDR is typically cached for faster subsequent access.
          However,  it  may need to be flushed and re-generated if the SDR
          has been updated on a system.

   -Q, --quiet-cache
          Do not output information about cache creation/deletion. May  be
          useful in scripting.

   --sdr-cache-recreate
          If  the  SDR  cache  is  out  of  date or invalid, automatically
          recreate the sensor data repository (SDR) cache. This option may
          be useful for scripting purposes.

   --sdr-cache-file=FILE
          Specify a specific sensor data repository (SDR) cache file to be
          stored or read from. If this option is used when multiple  hosts
          are  specified,  the  same  SDR  cache file will be used for all
          hosts.

   --sdr-cache-directory=DIRECTORY
          Specify an alternate directory for sensor data repository  (SDR)
          caches to be stored or read from. Defaults to the home directory
          if not specified.

   --ignore-sdr-cache
          Ignore SDR cache related processing. May lead to  incomplete  or
          less  useful  information  being  output,  however it will allow
          functionality for systems without SDRs or when the  correct  SDR
          cannot be loaded.

TIME OPTIONS

   By  IPMI  definition,  all  IPMI  times  and  timestamps  are stored in
   localtime. However, in many situations,  the  timestamps  will  not  be
   stored  in  localtime.  Whether  or  not  a  system  truly  stored  the
   timestamps in localtime varies on many factors,  such  as  the  vendor,
   BIOS,  and operating system.  The following options will allow the user
   to adjust the interpretation of the  stored  timestamps  and  how  they
   should be output.

   --utc-to-localtime
          Assume  all  times are reported in UTC time and convert the time
          to localtime before being output.

   --localtime-to-utc
          Convert all localtime timestamps to UTC before being output.

   --utc-offset=SECONDS
          Specify a  specific  UTC  offset  in  seconds  to  be  added  to
          timestamps.   Value  can  range  from  -86400  to 86400 seconds.
          Defaults to 0.

HOSTRANGED OPTIONS

   The following options  manipulate  hostranged  output.  See  HOSTRANGED
   SUPPORT below for additional information on hostranges.

   -B, --buffer-output
          Buffer  hostranged output. For each node, buffer standard output
          until the node has completed its IPMI operation. When specifying
          this  option, data may appear to output slower to the user since
          the the entire IPMI operation must complete before any data  can
          be   output.    See  HOSTRANGED  SUPPORT  below  for  additional
          information.

   -C, --consolidate-output
          Consolidate hostranged output. The complete standard output from
          every  node  specified  will  be consolidated so that nodes with
          identical output are not output twice. A header will list  those
          nodes   with  the  consolidated  output.  When  this  option  is
          specified, no output can be seen until the  IPMI  operations  to
          all  nodes  has completed. If the user breaks out of the program
          early, all currently consolidated output  will  be  dumped.  See
          HOSTRANGED SUPPORT below for additional information.

   -F NUM, --fanout=NUM
          Specify  multiple  host  fanout.  A "sliding window" (or fanout)
          algorithm is used for parallel IPMI communication so that slower
          nodes or timed out nodes will not impede parallel communication.
          The maximum number of threads available  at  the  same  time  is
          limited by the fanout. The default is 64.

   -E, --eliminate
          Eliminate  hosts  determined  as undetected by ipmidetect.  This
          attempts to remove the  common  issue  of  hostranged  execution
          timing  out due to several nodes being removed from service in a
          large cluster. The ipmidetectd daemon must  be  running  on  the
          node executing the command.

   --always-prefix
          Always  prefix  output,  even  if  only one host is specified or
          communicating in-band.  This  option  is  primarily  useful  for
          scripting purposes. Option will be ignored if specified with the
          -C option.

HOSTRANGED SUPPORT

   Multiple hosts can be input either as an explicit comma separated lists
   of  hosts  or  a  range of hostnames in the general form: prefix[n-m,l-
   k,...], where n < m and l < k,  etc.  The  later  form  should  not  be
   confused  with  regular  expression  character classes (also denoted by
   []). For example, foo[19] does not represent foo1 or foo9,  but  rather
   represents a degenerate range: foo19.

   This  range  syntax  is  meant only as a convenience on clusters with a
   prefixNN naming convention and specification of ranges  should  not  be
   considered  necessary -- the list foo1,foo9 could be specified as such,
   or by the range foo[1,9].

   Some examples of range usage follow:
       foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
       foo[7,9-10] instead of foo7,foo9,foo10
       foo[0-3] instead of foo0,foo1,foo2,foo3

   As a reminder to the reader, some shells will interpret brackets ([ and
   ])  for  pattern matching. Depending on your shell, it may be necessary
   to enclose ranged lists within quotes.

   When multiple hosts are  specified  by  the  user,  a  thread  will  be
   executed  for  each host in parallel up to the configured fanout (which
   can be adjusted via the -F option). This will  allow  communication  to
   large numbers of nodes far more quickly than if done in serial.

   By  default,  standard  output  from each node specified will be output
   with the hostname prepended to  each  line.  Although  this  output  is
   readable  in  many  situations,  it  may  be difficult to read in other
   situations. For example,  output  from  multiple  nodes  may  be  mixed
   together. The -B and -C options can be used to change this default.

   In-band  IPMI  Communication  will be used when the host "localhost" is
   specified.  This  allows  the  user  to  add  the  localhost  into  the
   hostranged output.

GENERAL TROUBLESHOOTING

   Most often, IPMI problems are due to configuration problems.

   IPMI  over  LAN  problems  involve  a  misconfiguration  of  the remote
   machine's BMC.  Double check to make sure the following are  configured
   properly  in  the remote machine's BMC: IP address, MAC address, subnet
   mask,  username,  user  enablement,  user  privilege,   password,   LAN
   privilege, LAN enablement, and allowed authentication type(s). For IPMI
   2.0  connections,  double  check  to  make  sure   the   cipher   suite
   privilege(s)  and  K_g  key are configured properly. The ipmi-config(8)
   tool can be used to check and/or change these configuration settings.

   Inband IPMI problems are  typically  caused  by  improperly  configured
   drivers or non-standard BMCs.

   In  addition  to the troubleshooting tips below, please see WORKAROUNDS
   below to also if there are any vendor  specific  bugs  that  have  been
   discovered and worked around.

   Listed  below  are  many  of the common issues for error messages.  For
   additional support, please e-mail the <freeipmi-users@gnu.org>  mailing
   list.

   "username  invalid"  - The username entered (or a NULL username if none
   was entered) is not available on the remote machine.  It  may  also  be
   possible the remote BMC's username configuration is incorrect.

   "password  invalid"  - The password entered (or a NULL password if none
   was entered) is not correct. It may also be possible the  password  for
   the user is not correctly configured on the remote BMC.

   "password  verification timeout" - Password verification has timed out.
   A "password invalid" error (described  above)  or  a  generic  "session
   timeout" (described below) occurred.  During this point in the protocol
   it cannot be differentiated which occurred.

   "k_g invalid" - The K_g key entered (or a NULL  K_g  key  if  none  was
   entered)  is  not  correct.  It may also be possible the K_g key is not
   correctly configured on the remote BMC.

   "privilege level insufficient" - An IPMI command requires a higher user
   privilege  than  the one authenticated with. Please try to authenticate
   with a higher privilege. This may require authenticating to a different
   user which has a higher maximum privilege.

   "privilege  level  cannot  be  obtained  for this user" - The privilege
   level you are attempting  to  authenticate  with  is  higher  than  the
   maximum allowed for this user. Please try again with a lower privilege.
   It may also be possible the maximum privilege level allowed for a  user
   is not configured properly on the remote BMC.

   "authentication  type  unavailable for attempted privilege level" - The
   authentication type you wish to authenticate with is not available  for
   this privilege level. Please try again with an alternate authentication
   type or  alternate  privilege  level.  It  may  also  be  possible  the
   available  authentication  types  you  can  authenticate  with  are not
   correctly configured on the remote BMC.

   "cipher suite id unavailable"  -  The  cipher  suite  id  you  wish  to
   authenticate  with is not available on the remote BMC. Please try again
   with an alternate  cipher  suite  id.  It  may  also  be  possible  the
   available  cipher  suite ids are not correctly configured on the remote
   BMC.

   "ipmi 2.0 unavailable" - IPMI 2.0 was  not  discovered  on  the  remote
   machine. Please try to use IPMI 1.5 instead.

   "connection  timeout"  - Initial IPMI communication failed. A number of
   potential errors are possible, including an invalid hostname specified,
   an  IPMI  IP  address  cannot  be  resolved, IPMI is not enabled on the
   remote server, the  network  connection  is  bad,  etc.  Please  verify
   configuration and connectivity.

   "session  timeout"  - The IPMI session has timed out. Please reconnect.
   If this error occurs often, you may wish to increase the retransmission
   timeout. Some remote BMCs are considerably slower than others.

   "device  not  found"  - The specified device could not be found. Please
   check configuration or inputs and try again.

   "driver timeout" - Communication with the driver or  device  has  timed
   out. Please try again.

   "message  timeout"  - Communication with the driver or device has timed
   out. Please try again.

   "BMC  busy"  -  The  BMC  is  currently  busy.  It  may  be  processing
   information  or  have  too many simultaneous sessions to manage. Please
   wait and try again.

   "could not find inband device" - An inband device could not  be  found.
   Please  check configuration or specify specific device or driver on the
   command line.

   "driver timeout" - The inband driver has timed out communicating to the
   local  BMC  or  service  processor. The BMC or service processor may be
   busy or (worst case) possibly non-functioning.

   "internal IPMI error" - An IPMI error has occurred that  FreeIPMI  does
   not  know  how  to  handle.  Please  e-mail <freeipmi-users@gnu.org> to
   report the issue.

IPMI-SEL TROUBLESHOOTING

   Some timestamps in the SEL may report a date of 1-Jan-1970,  the  epoch
   for  SEL  timestamps.  This  timestamp is not necessarily incorrect. It
   usually indicates a hardware event that occurred before a timestamp  in
   firmware has been initialized. For example, certain hardware components
   will have their internal clocks reset during a power cycle.

   However, if the internal clock of  the  SEL  appears  to  be  regularly
   incorrect,  you  may  need  to set the SEL time. This can be done using
   bmc-device(8).

   The following are common SEL related messages.

   "sel config file parse error" - A parse error  was  found  in  the  sel
   event     interpretation     configuration     file.     Please     see
   freeipmi_interpret_sel.conf(5).

WORKAROUNDS

   With so many different vendors implementing their own  IPMI  solutions,
   different  vendors  may implement their IPMI protocols incorrectly. The
   following describes a number  of  workarounds  currently  available  to
   handle  discovered  compliance  issues. When possible, workarounds have
   been implemented so they will be transparent to the user. However, some
   will  require  the  user  to  specify  a  workaround be used via the -W
   option.

   The hardware listed below may only indicate the hardware that a problem
   was  discovered  on.  Newer  versions  of hardware may fix the problems
   indicated below. Similar machines from vendors may or may  not  exhibit
   the  same  problems.  Different vendors may license their firmware from
   the same IPMI firmware developer,  so  it  may  be  worthwhile  to  try
   workarounds listed below even if your motherboard is not listed.

   If  you  believe  your hardware has an additional compliance issue that
   needs a workaround to  be  implemented,  please  contact  the  FreeIPMI
   maintainers on <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

   assumeio   -   This  workaround  flag  will  assume  inband  interfaces
   communicate with system I/O rather than being memory-mapped. This  will
   work  around  systems that report invalid base addresses. Those hitting
   this issue may see "device not supported" or  "could  not  find  inband
   device" errors.  Issue observed on HP ProLiant DL145 G1.

   spinpoll  -  This workaround flag will inform some inband drivers (most
   notably the KCS driver) to spin while polling rather than  putting  the
   process to sleep. This may significantly improve the wall clock running
   time of tools because an operating system scheduler's  granularity  may
   be  much larger than the time it takes to perform a single IPMI message
   transaction. However, by spinning, your system may be  performing  less
   useful work by not contexting out the tool for a more useful task.

   authcap  -  This  workaround  flag  will skip early checks for username
   capabilities, authentication capabilities, and K_g  support  and  allow
   IPMI  authentication  to  succeed.  It  works around multiple issues in
   which the remote system does not properly report username capabilities,
   authentication  capabilities,  or  K_g status. Those hitting this issue
   may  see  "username  invalid",  "authentication  type  unavailable  for
   attempted privilege level", or "k_g invalid" errors.  Issue observed on
   Asus  P5M2/P5MT-R/RS162-E4/RX4,  Intel  SR1520ML/X38ML,  and  Sun  Fire
   2200/4150/4450 with ELOM.

   nochecksumcheck  - This workaround flag will tell FreeIPMI to not check
   the checksums returned from IPMI command  responses.  It  works  around
   systems that return invalid checksums due to implementation errors, but
   the packet is otherwise valid. Users are cautioned on the use  of  this
   option,  as  it  removes  validation of packet integrity in a number of
   circumstances.  However,  it  is  unlikely  to  be  an  issue  in  most
   situations.  Those  hitting  this  issue  may see "connection timeout",
   "session timeout", or "password verification timeout" errors.  On  IPMI
   1.5  connections, the "noauthcodecheck" workaround may also needed too.
   Issue  observed  on  Supermicro  X9SCM-iiF,  Supermicro  X9DRi-F,   and
   Supermicro X9DRFR.

   idzero  -  This  workaround  flag  will  allow  empty session IDs to be
   accepted by the client. It works around IPMI sessions that report empty
   session  IDs  to  the client. Those hitting this issue may see "session
   timeout" errors. Issue observed on Tyan S2882 with M3289 BMC.

   unexpectedauth - This workaround flag will  allow  unexpected  non-null
   authcodes  to  be checked as though they were expected. It works around
   an issue when packets contain non-null authentication  data  when  they
   should  be  null  due  to  disabled  per-message  authentication. Those
   hitting this issue may see "session timeout" errors. Issue observed  on
   Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.

   forcepermsg   -   This   workaround   flag   will   force   per-message
   authentication to be used no matter what is advertised  by  the  remote
   system.  It  works  around  an issue when per-message authentication is
   advertised as disabled  on  the  remote  system,  but  it  is  actually
   required  for  the  protocol. Those hitting this issue may see "session
   timeout" errors.  Issue observed on IBM eServer 325.

   endianseq - This workaround flag will flip the endian  of  the  session
   sequence  numbers  to  allow the session to continue properly. It works
   around IPMI 1.5 session sequence numbers that  are  the  wrong  endian.
   Those  hitting  this  issue  may  see  "session  timeout" errors. Issue
   observed on  some  Sun  ILOM  1.0/2.0  (depends  on  service  processor
   endian).

   noauthcodecheck  - This workaround flag will tell FreeIPMI to not check
   the authentication codes returned from IPMI 1.5 command  responses.  It
   works  around  systems  that return invalid authentication codes due to
   hashing or implementation errors. Users are cautioned  on  the  use  of
   this  option,  as  it  removes  an  authentication  check verifying the
   validity of a packet. However, in most organizations, this is  unlikely
   to  be  a  security issue. Those hitting this issue may see "connection
   timeout", "session timeout", or "password verification timeout" errors.
   Issue   observed   on   Xyratex   FB-H8-SRAY,  Intel  Windmill,  Quanta
   Winterfell, and Wiwynn Windmill.

   intel20 - This workaround flag will work around several Intel IPMI  2.0
   authentication issues. The issues covered include padding of usernames,
   and password  truncation  if  the  authentication  algorithm  is  HMAC-
   MD5-128. Those hitting this issue may see "username invalid", "password
   invalid", or "k_g invalid" errors. Issue observed  on  Intel  SE7520AF2
   with Intel Server Management Module (Professional Edition).

   supermicro20 - This workaround flag will work around several Supermicro
   IPMI 2.0  authentication  issues  on  motherboards  w/  Peppercon  IPMI
   firmware.   The   issues   covered   include  handling  invalid  length
   authentication codes.  Those  hitting  this  issue  may  see  "password
   invalid"  errors.   Issue  observed  on  Supermicro  H8QME  with  SIMSO
   daughter card. Confirmed fixed on newerver firmware.

   sun20 - This workaround flag will work work around several Sun IPMI 2.0
   authentication issues. The issues covered include invalid lengthed hash
   keys, improperly hashed keys, and invalid cipher suite  records.  Those
   hitting  this  issue  may see "password invalid" or "bmc error" errors.
   Issue observed on Sun Fire 4100/4200/4500 with ILOM.   This  workaround
   automatically includes the "opensesspriv" workaround.

   opensesspriv - This workaround flag will slightly alter FreeIPMI's IPMI
   2.0 connection protocol to workaround an invalid hashing algorithm used
   by  the remote system. The privilege level sent during the Open Session
   stage of an IPMI 2.0 connection is used for hashing keys instead of the
   privilege  level  sent during the RAKP1 connection stage. Those hitting
   this issue may see "password invalid", "k_g invalid", or "bad  rmcpplus
   status  code"  errors.   Issue observed on Sun Fire 4100/4200/4500 with
   ILOM, Inventec 5441/Dell Xanadu II, Supermicro X8DTH, Supermicro X8DTG,
   Intel S5500WBV/Penguin Relion 700, Intel S2600JF/Appro 512X, and Quanta
   QSSC-S4R/Appro GB812X-CN. This workaround  is  automatically  triggered
   with the "sun20" workaround.

   integritycheckvalue  - This workaround flag will work around an invalid
   integrity check value during an IPMI  2.0  session  establishment  when
   using  Cipher Suite ID 0. The integrity check value should be 0 length,
   however the remote motherboard responds with a non-empty  field.  Those
   hitting  this  issue  may  see  "k_g invalid" errors. Issue observed on
   Supermicro X8DTG, Supermicro X8DTU, and Intel  S5500WBV/Penguin  Relion
   700, and Intel S2600JF/Appro 512X.

   assumemaxsdrrecordcount  -  This  workaround will inform SDR reading to
   stop reading after a known maximum numer of SDR records have been read.
   This  will  work  around  systems that have mis-implemented SDR reading
   functions that. Those hitting this issue  may  see  "SDR  record  count
   invalid" errors. Issue observed on unspecified Inspur motherboard.

   assumesystemevent  -  This  workaround  option  will assume invalid SEL
   record types  are  system  event  records.  Records  may  be  formatted
   correctly but report invalid record types. Those hitting this issue may
   see "Unknown SEL Record Type" errors. Output may be unknown,  pray  for
   the best. This option is confirmed to work around compliances issues on
   HP DL 380 G5 motherboards.

   No IPMI 1.5 Support - Some motherboards that support IPMI 2.0 have been
   found  to  not support IPMI 1.5. Those hitting this issue may see "ipmi
   2.0 unavailable" or "connection timeout"  errors.  This  issue  can  be
   worked  around  by  using  IPMI  2.0  instead of IPMI 1.5 by specifying
   --driver-type=LAN_2_0. Issue observed on HP Proliant DL 145.

OEM INTERPRETATION

   The following motherboards are confirmed to have atleast  some  support
   by  the --interpret-oem-data option. While highly probable the OEM data
   interpretations would  work  across  other  motherboards  by  the  same
   manufacturer,  there  are no guarantees. Some of the motherboards below
   may be rebranded by vendors/distributors.

   Dell Poweredge 2900, Dell Poweredge 2950,  Dell  Poweredge  R610,  Dell
   Poweredge   R710,   Fujitsu   iRMC   S1  and  iRMC  S2  systems,  Intel
   S5500WB/Penguin Computing Relion 700, Intel S2600JF/Appro  512X,  Intel
   S5000PAL,   Intel   Windmill,  Intel  S2600KP,  Intel  S2600WT2,  Intel
   S2600WTT, Inventec 5441/Dell Xanadu II, Inventec 5442/Dell Xanadu  III,
   Quanta  S99Q/Dell  FS12-TY,  Quanta  QSSC-S4R/Appro  GB812X-CN,  Quanta
   Winterfell, Sun X4140 Supermicro X7DBR-3, Supermicro X7DB8,  Supermicro
   X8DTN,   Supermicro  X7SBI-LN4,  Supermicro  X8DTH,  Supermicro  X8DTG,
   Supermicro   X8DTU,   Supermicro   X8DT3-LN4F,   Supermicro   X8DTU-6+,
   Supermicro  X8DTL,  Supermicro X8DTL-3F, Supermicro X8SIL-F, Supermicro
   X9SCL,  Supermicro  X9SCM,  Supermicro  X8DTN+-F,   Supermicro   X8SIE,
   Supermicro   X9SCA-F-O,   Supermicro   H8DGU-F,   Supermicro   X9DRi-F,
   Supermicro X9DRI-LN4F+,  Supermicro  X9SPU-F-O,  Supermicro  X9SCM-iiF,
   Wiwynn Windmill, Wistron/Dell Poweredge C6220.

EXAMPLES

   # ipmi-sel

   Show all SEL records on the local machine.

   # ipmi-sel -h ahost -u myusername -p mypassword

   Show all SEL records of a remote machine using IPMI over LAN.

   # ipmi-sel -h mycluster[0-127] -u myusername -p mypassword

   Show all SEL records across a cluster using IPMI over LAN.

   # ipmi-sel --delete=44,82

   Delete SEL records 44 and 82 on the local machine.

   # ipmi-sel --delete-all

   Delete all SEL entries on the local machine.

   # ipmi-sel --delete-range=12-42

   Delete SEL entries in the range 12 to 42 on the local machine.

DIAGNOSTICS

   Upon  successful  execution, exit status is 0. On error, exit status is
   1.

   If multiple hosts are specified for communication, the exit status is 0
   if  and  only  if  all targets successfully execute. Otherwise the exit
   status is 1.

KNOWN ISSUES

   On older operating systems, if you input your username,  password,  and
   other  potentially  security  relevant information on the command line,
   this information may be discovered by other users when using tools like
   the  ps(1) command or looking in the /proc file system. It is generally
   more secure to input password information with options like the  -P  or
   -K  options.  Configuring security relevant information in the FreeIPMI
   configuration file would also  be  an  appropriate  way  to  hide  this
   information.

   In  order  to  prevent  brute force attacks, some BMCs will temporarily
   "lock up" after a number of remote authentication errors. You may  need
   to  wait awhile in order to this temporary "lock up" to pass before you
   may authenticate again.

REPORTING BUGS

   Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.

COPYRIGHT

   Copyright  2003-2014 FreeIPMI Core Team.

   This program is free software; you can redistribute it and/or modify it
   under  the  terms of the GNU General Public License as published by the
   Free Software Foundation; either version 3 of the License, or (at  your
   option) any later version.

SEE ALSO

   freeipmi(7),      bmc-device(8),      ipmiseld(8),      ipmi-config(8),
   freeipmi_interpret_sel.conf(5)

   http://www.gnu.org/software/freeipmi/





Opportunity


Personal Opportunity - Free software gives you access to billions of dollars of software at no cost. Use this software for your business, personal use or to develop a profitable skill. Access to source code provides access to a level of capabilities/information that companies protect though copyrights. Open source is a core component of the Internet and it is available to you. Leverage the billions of dollars in resources and capabilities to build a career, establish a business or change the world. The potential is endless for those who understand the opportunity.

Business Opportunity - Goldman Sachs, IBM and countless large corporations are leveraging open source to reduce costs, develop products and increase their bottom lines. Learn what these companies know about open source and how open source can give you the advantage.





Free Software


Free Software provides computer programs and capabilities at no cost but more importantly, it provides the freedom to run, edit, contribute to, and share the software. The importance of free software is a matter of access, not price. Software at no cost is a benefit but ownership rights to the software and source code is far more significant.


Free Office Software - The Libre Office suite provides top desktop productivity tools for free. This includes, a word processor, spreadsheet, presentation engine, drawing and flowcharting, database and math applications. Libre Office is available for Linux or Windows.





Free Books


The Free Books Library is a collection of thousands of the most popular public domain books in an online readable format. The collection includes great classical literature and more recent works where the U.S. copyright has expired. These books are yours to read and use without restrictions.


Source Code - Want to change a program or know how it works? Open Source provides the source code for its programs so that anyone can use, modify or learn how to write those programs themselves. Visit the GNU source code repositories to download the source.





Education


Study at Harvard, Stanford or MIT - Open edX provides free online courses from Harvard, MIT, Columbia, UC Berkeley and other top Universities. Hundreds of courses for almost all major subjects and course levels. Open edx also offers some paid courses and selected certifications.


Linux Manual Pages - A man or manual page is a form of software documentation found on Linux/Unix operating systems. Topics covered include computer programs (including library and system calls), formal standards and conventions, and even abstract concepts.